Experimental and numerical investigation of therapeutic ultrasound angioplasty

Gavin, Graham P. (2005) Experimental and numerical investigation of therapeutic ultrasound angioplasty. PhD thesis, Dublin City University.

Abstract
Therapeutic ultrasound angioplasty is an emerging minimally invasive cardiovascular surgical procedure that involves the delivery of ultrasonic displacements to the distal-tip of small diameter wire waveguides. The ultrasonic distal-tip displacements affect atherosclerotic plaque and thrombus by direct contact ablation, pressure wave components and cavitation, in addition to an acoustic streaming event around the distal-tip. This study uses experimental and numerical methods to investigate ultrasonic displacements in wire waveguides and the effect the distal-tip displacements have on the surrounding fluid. An experimental therapeutic ultrasound wire waveguide apparatus is described that delivers displacements to the distal-tip of 1.0 mm and tapered 0.35 mm diameter nickel-titanium (NiTi) waveguides. The operating frequency of the apparatus has been experimentally determined to be 23.5 kHz and for the power settings tested delivers displacements of up to 85 |im peak-to-peak (p-p) to the distal-tip of 1.0 mm diameter waveguides. The apparatus has been shown to directly ablate calcified materials with a stiffer response when compared with atherosclerotic plaques and to generate cavitation and acoustic streaming. A coupled fluid-structure numerical model of the waveguide and fluid surrounding the distal-tip has been developed that predicts the waveguide displacements and stresses along the entire length of the wire waveguide. The structural results of the model have been validated against experimental measurements of the displacements of the waveguide with the inclusion of a constant damping value of 4.5%. The fluid results of the model predict the pressure amplitudes developed in the surrounding fluid and compare closely with values reported in literature. The model predicts the distal-tip displacements required to cause cavitation, a major disruptive event, and has been compared with experimental observations made with the ultrasonic wire waveguide apparatus. The waveguide numerical model will prove a valuable design tool in the further development and improvement of this emerging cardiovascular technology.
Metadata
Item Type:Thesis (PhD)
Date of Award:2005
Refereed:No
Supervisor(s):McGuinness, Garrett
Uncontrolled Keywords:Therapeutic ultrasound angioplasty; distal-tip displacements; ultrasonic displacements; atherosclerotic plaque
Subjects:Engineering > Mechanical engineering
Engineering > Biomedical engineering
DCU Faculties and Centres:DCU Faculties and Schools > Faculty of Engineering and Computing > School of Mechanical and Manufacturing Engineering
Use License:This item is licensed under a Creative Commons Attribution-NonCommercial-No Derivative Works 3.0 License. View License
ID Code:17300
Deposited On:28 Aug 2012 11:15 by Fran Callaghan . Last Modified 19 Jul 2018 14:56
Documents

Full text available as:

[thumbnail of graham_p._gavin_20120702145645.pdf]
Preview
PDF - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
4MB
Downloads

Downloads

Downloads per month over past year

Archive Staff Only: edit this record