Login (DCU Staff Only)
Login (DCU Staff Only)

DORAS | DCU Research Repository

Explore open access research and scholarly works from DCU

Advanced Search

Probing the functionality of ion-selective membranes using electrochemical impedance spectroscopy: towards 'calibrationless' sensors

Radu, Aleksandar, Anastasova, Salzitsa and Diamond, Dermot orcid logoORCID: 0000-0003-2944-4839 (2009) Probing the functionality of ion-selective membranes using electrochemical impedance spectroscopy: towards 'calibrationless' sensors. In: PITTCON 2009 - 60th Pittsburg Conference on Analytical Chemistry and Applied Spectroscopy, 8-13 March 2009, Chicago, USA.

Abstract
The vision of widely deployed wireless chemical sensing networks (WCSNs),depends on the availability of simple, low cost, low power chemical sensors. Due to their simple construction, yet excellent selectivity and sensitivity, ion-selective electrodes (ISEs) are excellent candidates for integration into such devices. Typical parameters used in characterisation of ISEs are slope, baseline, selectivity, limit of detection and the calibration is used to check these parameters and decide whether one or more of these parameters has crossed an “unacceptable” threshold, and the device is no longer reliable. Unfortunately, current designs of autonomous, deployable chemical sensing devices necessary include pumps, valves, and containers for calibration solutions and waste storage, whichraises the costs of such devices to levels that render their integration into WCSNs impossible.In contrast, physical transducers like thermistors are typically subjected to a range of electrical tests to assess their functionality by probing their resistance, impedance, conductance etc. The question we ask here is whether such tests can provide enough information to profile a chemical sensor’s functionality without having to employ reference solutions. For example, AC impendancecan give an insight into whether the bulk or interfacial characteristics have changed significantly due to physical damage, leaching of the membrane components or due to poisoning of the interface by biofoulingas well as by sample components.We show here initial results that suggest such tests enable the state of a chemical sensor to be profiled to some extentwithout liquid handling.
Metadata
Item Type:Conference or Workshop Item (Invited Talk)
Event Type:Conference
Refereed:No
Subjects:Physical Sciences > Analytical chemistry
Physical Sciences > Chemical detectors
Physical Sciences > Electrochemistry
DCU Faculties and Centres:DCU Faculties and Schools > Faculty of Science and Health > School of Chemical Sciences
Research Institutes and Centres > National Centre for Sensor Research (NCSR)
Research Institutes and Centres > CLARITY: The Centre for Sensor Web Technologies
Official URL:http://www.pittcon.org/
Use License:This item is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 3.0 License. View License
Funders:Science Foundation Ireland, SFI 07/CE/I1147
ID Code:2970
Deposited On:06 Apr 2009 14:37 by Aleksandar Radu . Last Modified 18 Sep 2018 15:26
Documents

Full text available as:

[thumbnail of Abstract]
Preview
PDF (Abstract) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
452kB
[thumbnail of Slides]
Preview
PDF (Slides) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
3MB
Downloads

Downloads

Downloads per month over past year

Archive Staff Only: edit this record