Login (DCU Staff Only)
Login (DCU Staff Only)

DORAS | DCU Research Repository

Explore open access research and scholarly works from DCU

Advanced Search

Ion-selective electrodes in real-life applications: can we reduce or even eliminate the need for calibration?

Radu, Aleksandar, Anastasova, Salzitsa, Radu, Tanja, Dillingham, Peter, McGraw, Christina, Danielewski, Marek, Bobacka, Johan and Diamond, Dermot orcid logoORCID: 0000-0003-2944-4839 (2008) Ion-selective electrodes in real-life applications: can we reduce or even eliminate the need for calibration? In: Matrafured 2008, 5-10 October 2008, Dobogoko, Hungary.

Abstract
The recent success in lowering of the low detection limit of ion-selective electrodes (ISEs) has opened up new application areas (most notably environmental analysis). The new possibilities have intensified issues that weren’t critical in other application fields. In particular, the potential of ISEs to be integrated as detector systems in autonomous, deployable devices for environmental analysis have opened the question of the measure of uncertainty in prediction of unknown concentration based on calibration as well as the necessity of reduction or even elimination of calibration itself. Here we point out the need for the maximal efficiency of using obtained results based on utilization of solid-contact ISEs for heavy metal analysis in soil. We advocate altering the current definition of detection limit and using signal-to-noise ratio as suggested earlier by Bakker and Pretsch.[1] We also suggest new method for jointly estimating the calibration curve and the unknown concentrations using all the data. This method is in statistical analysis called Bayesian analysis. It allows more accurate prediction of unknown concentration, especially near and even below the detection limit. Furthermore, it allows using of multiple sensors (without disregarding poor performing sensors) which will allow further tightening of the prediction intervals. Finally, we will present initial work on developing “calibrationless” chemical sensors where we use ISEs as model system. We are developing tests that will enable us to understand whether the surface or the bulk of the membrane has been altered (i.e. due to biofouling or poisoning of the electrode surface) thus avoiding the need to re-calibrate the sensors. [1] Bakker E. Pretsch E; Trends Anal. Chem.; 2005, 24, (3), 199
Metadata
Item Type:Conference or Workshop Item (Lecture)
Event Type:Conference
Refereed:No
Uncontrolled Keywords:statistics;
Subjects:Physical Sciences > Analytical chemistry
Physical Sciences > Electrochemistry
DCU Faculties and Centres:DCU Faculties and Schools > Faculty of Science and Health > School of Chemical Sciences
Research Institutes and Centres > National Centre for Sensor Research (NCSR)
Official URL:http://www.matrafured-08.ethz.ch/
Use License:This item is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 3.0 License. View License
ID Code:2973
Deposited On:06 Apr 2009 14:01 by Aleksandar Radu . Last Modified 18 Sep 2018 13:50
Documents

Full text available as:

[thumbnail of abstract]
Preview
PDF (abstract) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
462kB
[thumbnail of presentation slides]
Preview
PDF (presentation slides) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
2MB
Downloads

Downloads

Downloads per month over past year

Archive Staff Only: edit this record