Benito-Lopez, Fernando ORCID: 0000-0003-0699-5507, Coyle, Shirley ORCID: 0000-0003-0493-8963, Byrne, Robert, Smeaton, Alan F. ORCID: 0000-0003-1028-8389, O'Connor, Noel E. ORCID: 0000-0002-4033-9135 and Diamond, Dermot ORCID: 0000-0003-2944-4839 (2009) Pump less wearable microfluidic device for real time pH sweat monitoring. In: Eurosensors 2009, 6-9 Sept 2009, Lausanne, Switzerland. ISBN 1876-6196
Abstract
This paper presents the fabrication and the performance of a novel, wearable, robust, flexible and disposable
microfluidic device which incorporates micro-Light Emitting Diodes (μ-LEDs) as a detection system, for
monitoring in real time mode the pH of the sweat generated during an exercising period.
Metadata
Item Type: | Conference or Workshop Item (Poster) |
---|---|
Event Type: | Conference |
Refereed: | Yes |
Uncontrolled Keywords: | microfluidic; pH; sport science; sweat monitoring; wearable sensors |
Subjects: | Engineering > Systems engineering Medical Sciences > Health Physical Sciences > Chemistry Medical Sciences > Physiology Medical Sciences > Sports sciences |
DCU Faculties and Centres: | DCU Faculties and Schools > Faculty of Science and Health > School of Chemical Sciences DCU Faculties and Schools > Faculty of Science and Health > School of Health and Human Performance Research Institutes and Centres > National Centre for Sensor Research (NCSR) Research Institutes and Centres > CLARITY: The Centre for Sensor Web Technologies |
Published in: | Procedia Chemistry. 1(1). Elsevier. ISBN 1876-6196 |
Publisher: | Elsevier |
Official URL: | http://dx.doi.org/10.1016/j.proche.2009.07.275 |
Use License: | This item is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 3.0 License. View License |
Funders: | Irish Research Council for Science Engineering and Technology, IRCSET fellowship number 2089, Science Foundation Ireland, SFI 07/CE/I1147, European Union (Biotex FP6-2004-IST-NMP-2) |
ID Code: | 14800 |
Deposited On: | 14 Sep 2009 10:21 by Fernando Benito-Lopez . Last Modified 05 May 2022 14:27 |
Documents
Full text available as:
Preview |
PDF
- Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
253kB |
Downloads
Downloads
Downloads per month over past year
Available Versions of this Item
-
Pump less wearable microfluidic device for real time pH sweat monitoring. (deposited 14 Sep 2009 12:59)
- Pump less wearable microfluidic device for real time pH sweat monitoring. (deposited 14 Sep 2009 10:21) [Currently Displayed]
Archive Staff Only: edit this record